  307 disconnects disconnects section contents page safety module? fused disconnect switch ..... 308-309 coordination module? fused lighting and appliance panelboard ...................... 310-311 power module? all-in-one elevator disconnect ....................... 312-313 fusible disconnects overview for compact series .......................314 30a base & din rail mount compact series switches ................................... 315-316 60-100a base & din rail mount compact series switches ......................................317 accessories for 60-100a compact series switches ......................................318 200-800a base & din rail mount compact series switches .................................. 319-320 30C800a, 600v 3-pole compact series enclosed switches ................................... 321-322 30C800a 2-, 4- & 6-pole compact series enclosed switches ................................... 323-324 non-fusible disconnects overview for compact series non-fusible switches 16-125a ...............................325 overview for compact series non-fusible switches 175-3150a .............................326 16-100a compact series base & din rail mount switches .................................. 327-328 16-100a compact series door mounted switches .... .329 400-800a compact series non-fusible switches ....... 330 accessories for 400-800a compact series switches ....331 16C80a, 600v 3-pole compact series non-fusible enclosed switches ..............................332 16a-3150a, 600v 3-pole compact series non-fusible enclosed switches .............................. 333 16-400a 2-, 4- & 6-pole compact series non-fusible enclosed switches ........................... 334-335 a/c disconnects fused and non-fused ..........336 fused, dead front disconnect switches ...........337 red indicates new information
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 308 disconnects safety module fused disconnect switch sm363 _ _ cooper bussmann safety module specifications description: a fused disconnect featuring enhanced safety features and use of the cooper bussmann ? cubefuse ? . optional rejection kits prevent overfusing 30 and 60 amp circuits. padlockable handle and door interlock provide safety during maintenance procedures. viewing window permits viewing cubefuse permanent fuse indication status without opening the door. poles: 3 enclosures: nema 1, 3r, 12 and 4x ratings: volts: 600vac amps: 0-100a sccr: 50ka agency information: ce, ul listed and cul listed. features and benefits ? easyid ? fuse viewing window allows maintenance personnel to quickly identify open fuses without opening the enclosure. ? wide amp range in one unit provides installation flexibility one safety module? covers 1-100a applications. ? rejection kits prevent overfusing 30a and 60a circuits. ? optional internal safety barrier covers all energized parts to provide added protection against electrical hazards even with the enclosure door open. accessories ? optional internal safety barriers ? solid neutral terminal ? auxiliary contacts ? rejection kits for 30 and 60 amp applications catalog numbers catalog amp nema max. hp rating dimensions (in)** numbers* rating enclosure 240v 480v 600v height width depth sccr SM363FG 100 1 20 40 50 16 8 5 50ka sm363fr 100 3r 20 40 50 16 12 5 50ka sm363fd 100 12 20 40 50 16 10 6 50ka sm363fx 100 4xss 20 40 50 16 12 6 50ka * for safety barrier/rejection plate, add the suffix b to the catalog number, then add either; 1 for 30a, 2 for 60a or 3 for 10 0a. example: SM363FGb3. nema 1 enclosures also available in gray. to order, place suffix g to the end of catalog number. example: SM363FGg. nema 3r & 12 only available in gray. ** does not include mounting tabs or handle. see data sheet for full dimensional data.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 309 disconnects safety module fused disconnect switch padlockable handle with up to three padlocks to protect maintenance personnel. conduit knockouts for easy installation. field installed accessories ? solid neutral terminal ? auxiliary contacts ? internal lockable handle ? rejection kit for 30 and 60 amp applications nema 1, 3r, 12 & 4x enclosures meet most application requirements. high visibility safety yellow easy to locate and identify disconnect means. also available in standard gray. viewing window quick identification of fuse condition without opening the door. fuse base accepts 1-100a fuses (rejection kits available). cubefuse ? class j time-delay electrical performance. ? easyid ? permanent replace fuse indication to quickly determine fuse condition. ? finger-safe test points allow testing voltage without exposure to energized conductors. positive opening operation contacts are opened and closed by a driven mechanism (not springs) so the switch cannot reach the off position unless the contacts are truly open. optional safety barrier covers energized parts to provide added protection against electrical hazards. door interlock prevents opening door while energized, but can be overridden for testing or inspection.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 310 coordination module* branch circuit voltage dimensions (in) main device amp number of catalog numbers rating sccr height width depth type amp rating rating circuits ep2m23012gcc 120/208 100ka** 36 28 5 3 ? 4 mlo 200 30 12 ep2m23024gcc 120/208 100ka** 38 28 5 3 ? 4 mlo 200 30 24 ep2m23036gcc 120/208 100ka** 48 28 5 3 ? 4 mlo 200 30 36 ep2m23042gcc 120/208 100ka** 48 28 5 3 ? 4 mlo 200 30 42 ep4m23012gcc 277/480 100ka*** 36 28 5 3 ? 4 mlo 200 30 12 ep4m23024gcc 277/480 100ka*** 36 28 5 3 ? 4 mlo 200 30 24 ep4m23036gcc 277/480 100ka*** 48 28 5 3 ? 4 mlo 200 30 36 ep4m23042gcc 277/480 100ka*** 48 28 5 3 ? 4 mlo 200 30 42 * meets ul 67 (panelboards) and ul 50 (cabinets and boxes). ** when protected by upstream lpn-rk 100a max. lpj 200a max. or jjn 200a max., otherwise 10ka. *** when protected by upstream lpn-rk 200a max. lpj 200a max. or jjn 200a max., otherwise 14ka. coordination module fused lighting and appliance panelboard disconnects type ep cooper bussmann coordination module specifications description: a fused lighting and appliance panelboard for branch circuit applications. specifically designed to meet the 2005 nec ? code requirements for selective coordination for emergency, legally required standby and essential electrical systems per 700.27, 701.18, and 517.26 when properly coordi- nated with the upstream overcurrent protective device feeder. circuits: 12, 24, 36, 42 enclosure: nema 1 ratings: volts: 120/208 or 277/480vac branch circuit amps: 0-30a sccr: 100ka agency information: ul67, ul 50. features and benefits ? complies with the new 2005 nec ? selective coordination requirements for emergency, legally required standby and essential electrical systems per 700.27, 701.18, and 517.26 when properly coordinated with the upstream overcurrent protective device feeder. per the 2005 nec ? : coordination (selective) is the localization of an overcurrent condition to restrict outages to the circuit or equipment affected, accomplished by the choice of overcurrent protective devices and their ratings or settings. ? ensures system uptime with the goal of safety of human life during emergencies or for essential health care functions. ? provides a fast and easy solution to meeting new coordination code requirements. simply utilize published fuse selective coordination ratios to select the correct upstream fuse ratings. ? offers significant savings compared to other fused panels and selectively coordinated circuit breaker systems. typical applications ? hospitals ? schools ? commercial and industrial facilities catalog numbers
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 311 coordination module fused lighting and appliance panelboard disconnects data sheet: 1154 ground bar bolted with set screw terminations. 200a copper main bus 12 to 42 circuits 120/208v or 277/480v main lugs with agw 6-300kcmil terminations. branch circuit breakers provide circuit isolation. nema type 1 enclosure with surface mount trim. class cc fuse holders with easyid neon indicator provides ease of coordination with superior overcurrent protection and open fuse indication. full-sized neutral bar with set-screw terminations.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 312 disconnects power module ?all-in-one elevator disconnect ps data sheet: 1145 pmp data sheet: 1146 pmp power module? panel for multiple elevator applications ps power module? switch for single elevator applications ps & pmp cooper bussmann power module specifications description: fusible power switch with shunt trip and fire safety interface to allow for single point tie in with fire alarm system. ratings: volts: 600vac, 3? amps: 30-400a (ps) 30-400a (pmp feeder switches) 400-800a (pmp main switches*) sccr: 200,000a rms *contact cooper bussmann for applications greater than 800a. agency information: complies with nfpa 70 (nec ? ; national electrical code ? ), ansi/asme a17.1 (safety code for elevators and escalators), nfpa 72 (national fire alarm code ? ) power module switch; ul listed (ul 98) enclosed and dead front switch guide 96nk3917, file e182262, nema 1, ul 50 listed enclosure**, ulc per canadian standards c22.2, no. 0-m91-can/csa c22.2, no. 4-m89 enclosed switch. **nema 12, 3r, and 4 enclosures also available power module panel; ul listed (ul 67) panel boards or (ul 891) dead front switchboard, file e181664, ulc per canadian standards, service entrance rated. features and benefits ? internally powered, relay activated shunt trip system. ? mechanically interlocked auxiliary contact. ? self-contained adherence to elevator consensus standards, nfpa 70 (nec ? ). nfpa 72, ansi/asme 17.1. typical applications ? elevator disconnects ? computer room shunt trip disconnect ? fire safety interface relay accessories ? for added safety, use the cooper bussmann sami? fuse covers to improve maintenance personnel protection (osha 1910.333, paragraph c). ordering the cooper bussmann power module switch and panel are factory configured to the specific application. contact your cooper bussmann representative to place your order. have all relevant electrical and circuit information on hand.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 313 disconnects disconnects power module ?all-in-one elevator disconnect the power module? is the best choice for design engineers or electrical contractors that need to meet these requirements, codes and standards: ? elevator shutdown C ansi/asme a17.1 rule 102.2(c)(3) ? shunt trip voltage monitoring C nfpa 72-1999 3-9.4.4 ? integrity monitoring C nfpa 72-1999 3-9.2.1 ? allows elevator shutdown C nec ? 620.51 ? selective coordination C nec ? 620.62 ? auxiliary contact (hydraulic elevator) C nec ? 620.91(c) ? orderly shutdown C nec ? 240.12 with the power module you get: ? shunt trip capability ? selective coordination ? fire safety signal interface ? shunt trip voltage monitoring ? component protection via low-peak ? class j fuses ? ul 98 listed for 200ka short-circuit current rating ? lockable in the open position with three lock capability ? optional key-test switch and optional pilot light for easy inspection ? no annual calibration or testing of overcurrent protection required ? padlockable for service work safety and open door override for troubleshooting notes: always f ollow estab lished saf ety practices when wor king on a electrically live equipment. hydraulic elevators hydraulic elevators need battery backup to help prevent stranding passengers. to keep the elevator from moving when its been manually shut down for maintenance, the nec ? requires battery backup be connected to the elevator disconnecting means through an auxillary contact. however, an unintended consequence can be passengers getting stranded because of devices that open automatically (circuit breakers and disconnects utilizing a molded case switch with a trailing fuse block) will operate with a fault on their loadside. that operation also disables the battery backup and strands passengers. thats why the power module has a non-automatic fusible shunt trip switch. if the power module has a fault on its loadside, the fuses open and the battery stays enabled. thus the power module ensures that battery power is enabled when the passengers need it to exit, and disabled to allow safe main- tenance of the elevator and hoistway. battery offered by offered by lowering power other elevator scenario required reason module disconnects power failure yes need to lower elevator to allow passengers to exit yes yes fire in shaft or recall is initiated by smoke detector and lowers elevator to machine room no a safe floor. battery not needed yes yes disconnect manually worker to perform maintenance. elevator must remain opened no stationary to prevent injury yes yes fault on loadside of need to lower elevator to allow passengers to exit yes no disconnect yes power module p anel (pmp)
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 314 disconnects overview for compact series fusible disconnect switches cfd60j3 fd400j3 agency information: ul listed, csa certified, iec rated, ce marked. catalog numbers 3-pole cfd30cc3 cfd30j3 cfd60j3 cfd100j3 fd200j3 fd400j3 fd600j3 fd800l3 general purpose amp ratings a 30 30 60 100 200 400 600 800 approvals(1) 2-pole n/a n/a n/a ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec 3-pole ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec 4-pole ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec technical ratings (ul,csa) max operating voltage v 600 600 600 600 600 600 600 600 max horsepower rating three phase 200-208v hp 5/7.5 5/7.5 15 25 50 100/125 150 200 240v hp 7.5 7.5 15 30 60 125 200 250 480v hp 15 15 30 60 125 250 400 500 600v hp 20 20 50 75 150 350 500 600 single phase 120v hp 2 2 240v hp 3 3 ul fuse class cc jjjj,tj,tj,tl short-circuit rating with fuses ka 200 200 200 200 200 200 200 200 ul fuse size a 30 30 60 100 200 400 600 800 ul fuse type j/cc j j/t j/t j/t j/t j/t l technical ratings (iec) rated insulation and operational voltage. ac20 and dc20(2) 1000 1000 750 750 1000 1000 1000 1000 rated thermal current, ith ac 20/dc 20 open a 32 32 63 125 250 400 630 800 ac 20/dc 20 enclosed a 32 32 63 125 250 400 600 720 ac 21a 500v a 32 32 63 125 250 400 630 800 690v a 32 32 63 125 250 400 630 800 rated operational power ac 23 400/415v kw 14/15 14/15 30 80/90 132/140 210/230 315/340 350/380 690v kw 25 25 60 132 230 330 540 600 physical characteristics weight 3-pole switch lb 1.54 1.54 2.86 3.30 15.21 17.2 37.48 37.48 4-pole lb 1.98 1.98 3.52 3.96 17.4 19.4 46.3 46.3 dimension 3-pole h in 3.82 3.82 3.94 5.66 7.87 7.87 11.42 11.42 w in 4.17 4.17 5.63 7.06 10.31 11.22 14.69 14.69 d in 4.21 4.21 5.04 5.09 7.83 8.11 9.21 9.21 (1) ul listed switches are also csa certified (2) 1000v iec 408 cfd30cc3 to fd800l3 cfd100j3
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 315 disconnects disconnects 30a base & din rail mount compact series fusible disconnect switches catalog shaft length mounting depth(1) numbers in (mm) in inches cds85s 3.3 (85) 5.5-5.7 cds105s 4.1 (105) 5.5-6.5 cds120s 4.7 (120) 5.5-7.1 cds130s 5.1 (130) 5.5-7.5 cds180s 7.1 (180) 6.3-9.4 cds250s 9.8 (250) 9.1-12.2 cds330s 13.0 (330) 12.2-15.4 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. handle - selector 30a ul fuse class j, cc for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle cfd30j3 cds_ _s ul general fuse maximum horsepower rating terminal catalog purpose type three phase lugs wire numbers poles amp rating 600v 200v 208v 240v 480v 600v size/type cfd30j3 3 30 j 5 7.5 7.5 15 20 #18 C 8/cu cfd30cc3 3 30 cc 5 7.5 7.5 15 20 #18 C 8/cu cfd30j4 4 30 j 5 7.5 7.5 15 20 #18 C 8/cu cfd30cc4 4 30 cc 5 7.5 7.5 15 20 #18 C 8/cu cdh4s, 6s handle - selector ?for use with shafts  0.20 x 0.20" (  5 x 5 mm) all marked both o/i & off/on catalog nema iec numbers type type color defeatable padlockable cdh3s 1,3r,12 ip65 black yes cdh4s 1,3r,12 ip65 red/yellow yes cdh5s 1,3r,12 ip65 black yes yes cdh6s 1,3r,12 ip65 red/yellow yes yes shafts ?for use with cdh selector handles  0.20 x 0.20" (  5 x 5 mm) 30a/600v switches
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 316 disconnects 30a base & din rail mount compact series fusible disconnect switches catalog shaft length mounting depth (1) number in (mm) in inches cds48p 5.9 (150) 4.9-8.9 cds67p 6.7 (170) 5.9-9.7 cds49p 10.4 (265) 9.5-13.4 cds50p 15.8 (400) 15.0-18.7 cds99p 19.7 (500) 20.5-22.6 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. catalog nema iec length numbers type type color marking in (mm) defeatable padlockable bdh104 1,3r,12 ip65 black o/i&off/on 1.8 (45) yes yes bdh105 1,3r,12 ip65 red/yellow o/i&off/on 1.8 (45) yes yes bdh106 1,3r,12 ip65 black o/i&off/on 2.6 (65) yes yes bdh107 1,3r,12 ip65 red/yellow o/i&off/on 2.6 (65) yes yes cdhxb65 1,3r,4,4x,12 ip65 black o/i&off/on 2.6 (65) yes yes cdhxy65 1,3r,4,4x,12 ip65 red/yellow o/i&off/on 2.6 (65) yes yes bdh106t 1,3r,12 ip65 black off/on/test 2.6 (65) yes yes bdh107t 1,3r,12 ip65 red/yellow off/on/test 2.6 (65) yes yes handle - pistol 30a ul fuse class j, cc for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle cds__ __p bdh104, 106 catalog nema length number type color marking in (mm) padlockable bdh79 1 black o/i/test 5.2 (132) yes ul general fuse maximum horsepower rating terminal catalog purpose type three phase lugs wire numbers poles amp rating 600v 200v 208v 240v 480v 600v size/type cfd30j3 3 30 j 5 7.5 7.5 15 20 #18 C 8/cu cfd30cc3 3 30 cc 5 7.5 7.5 15 20 #18 C 8/cu cfd30j4 4 30 j 5 7.5 7.5 15 20 #18 C 8/cu cfd30cc4 4 30 cc 5 7.5 7.5 15 20 #18 C 8/cu cfd30j3 switches 30a/600v shafts for use with pistol handles  0.20 x 0.20" (  5 x 5 mm) handles - pistol for use with shafts  0.20 x 0.20" (  5 x 5 mm) handle - direct mount mounts directly to switch, no shaft necessary 5.20" 132 mm bdh79 5.20"/132mm bdh79 mounted depth bdh79 mounted
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 317 disconnects disconnects shafts - twisted rotates handle 45  0.24 x 0.24" (  6 x 6 mm) catalog shaft length mounting depth (1) numbers in (mm) in inches bdst4 5.1 (130 4.8-7.8 bdst25 8.3 (210 8.0-11.0 bdst29 11.4 (290 11.0-14.0 bdst30 14.2 (360 13.8-16.8 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. shafts ?  0.24 x 0.24" (  6 x 6 mm) catalog shaft length mounting depth (1) numbers in (mm) in inches bds150 5.9 (150) 5.5-8.5 bds210 8.3 (210) 8.0-11.0 bds290 11.4 (290) 11.0-14.0 bds360 14.2 (360) 13.8-16.8 bds430 16.9 (430) 16.5-19.7 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. 60-100a base & din rail mount compact series fusible disconnect switches bdh59, 61 handle - pistol 60-100a ul fuse class j for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle ? 1 terminal lug kit bds__ cfd60j switches 60?00a/600v ul general ul fuse maximum horsepower rating catalog purpose type three phase number poles amp rating 600v 200v 208v 240v 480v 600v cfd60j3 3 60 j 15 15 15 30 50 cfd100j3 3 100 j 25 25 30 60 75 cfd60j4 4 60 j 15 15 15 30 50 cfd100j4 4 100 j 25 25 30 60 75 handles - pistol ?  0.24 x 0.24" (  6 x 6 mm) catalog nema iec length numbers type type color in (mm) marking defeatable padlockable bdh58 1,3r,12 ip65 black 2.6 (65) o/i & off/on yes yes bdh59 1,3r,12 ip65 red/yel 2.6 (65) o/i & off/on yes yes bdh60 1,3r,12 ip65 black 3.1 (80) o/i & off/on yes yes bdh61 1,3r,12 ip65 red/yel 3.1 (80) o/i & off/on yes yes cdhxb86 1,3r,4,4x,12 ip65 black 3.1 (80) o/i & off/on yes yes cdhxy86 1,3r,4,4x,12 ip65 red/yel 3.1 (80) o/i & off/on yes yes direct mount handle mounts directly to switch, no shaft necessary catalog nema number type color marking length(mm) padlockable cdh4 1 black o/i/test 50 yes
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 318 disconnects accessories for 60-100a compact series fusible disconnect switches ndna100 cdaux10 cdaux01k bdtl24 cfc60j cfcvr100 cfts100 cfz1 terminal lug kit catalog wire terminal numbers for use on: wire size type lugs per kit integral cfd60j_ #14-4 cu bdtl24 cfd100j_ #14-2/0 cu/al 6 auxiliary contacts catalog ac thermal ac rated numbers description for use on: amp rating voltage cdaux10 1 no 10 600 cdaux01k 1 nc cfd60 C cfd100 10 600 replacement fuse clip catalog number description for use on: cfc60j removable fuse carrier cfd60 replacement fuse covers catalog number description for use on: cfcvr100 transparent fuse cover cfd100 terminal shroud catalog number description for use on: cfts100 includes one terminal shroud for line or load side cfd100, 1-pole terminal poles catalog ac thermal ac rated numbers description for use on: amp rating voltage cfz1 detachable neutral cfd60 63 600 cfz2 mounts on side of switch or din rail cfd100 125 din rail catalog length numbers description for use on: in(cm) ndna100 35mm aluminum din rail cfd60 39.4 (100) ? type fuse adapter kit catalog number description for use on: bdta1 100a, 600v cfd100 bdta1
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 319 disconnects disconnects shafts - twisted rotates handle 45  0.47 x 0.47" (  12 x 12 mm) catalog shaft length mounting depth (1) number in (mm) in inches for use on fd200j_ ?fd400j_ bds28045 11.0 (280) 10.2-14.5 bds32545 12.8 (325) 12.0-16.3 bds46545 18.3 (465) 17.5-21.9 for use on fd600j_ ?fd800j_ bds28045 11.0 (280) 11.2-14.0 bds32545 12.8 (325) 13.0-15.8 bds46545 18.3 (465) 18.5-21.3 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. shafts ?  0.47 x 0.47" (  12 x 12 mm) catalog shaft length mounting depth(1) number in (mm) in inches for use on fd200j_ ?fd400j_ bds220 8.7 (220) 7.9-12.2 bds250 9.8 (250) 9.1-13.4 bds280 11.0 (280) 10.2-14.5 bds325 12.8 (325) 12.0-16.3 bds395 15.6 (395) 14.8-19.1 bds465 18.3 (465) 17.5-21.9 bds535 21.1 (535) 20.3-24.6 for use on fd600j_ ?fd800j_ bds250 9.8 (250) 10.0-12.8 bds280 11.0 (280) 11.2-14.0 bds325 12.8 (325) 13.0-15.8 bds395 15.6 (395) 15.8-18.6 bds465 18.3 (465) 18.5-21.3 bds535 21.1 (535) 21.1-24.1 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. 200-800a base & din rail mount compact series fusible disconnect switches handle - pistol 200-800a ul fuse class j, t, l for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle ? 1 terminal lug kit fd600j3 fd800l3 bds_ switches 200?00a, 600v ul general ul fuse maximum horsepower rating catalog purpose type three phase number poles amp rating 600v 200v 208v 240v 480v 600v fd200j2 2 200 j(1) fd400j2 2 400 j(1) fd600j2 2 600 j(1) fd800l2 2 800 l fd200j3 3 200 j(1) 50 50 60 125 150 fd400j3 3 400 j(1) 100 125 125 250 350 fd600j3 3 600 j(1) 150 150 200 400 500 fd800l3 3 800 l 200 200 250 500 600 fd200j4 4 200 j(1) 50 50 60 125 150 fd400j4 4 400 j(1) 100 125 125 250 350 fd600j4 4 600 j(1) 150 150 200 400 500 fd800l4 4 800 l 200 200 250 500 600 (1) j type fuse clips are standard. if 600v type t clips are desired, please order a "t" type fuse adapter kit. bdh114 bdtl25
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 320 disconnects 200-800a base & din rail mount compact series fusible disconnect switches bdta bdtl175/400 handles - pistol ?  0.47 x 0.47" (  12 x 12 mm) catalog nema iec length numbers type type color in (mm) marking defeatable padlockable bdh112 1,3r,12 ip65 black 4.9 (125) o/i & off/on yes yes bdh113 1,3r,12 ip65 red/yellow 4.9 (125) o/i & off/on yes yes bdh114 1,3r,12 ip65 black 5.7 (145) o/i & off/on yes yes bdh115 1,3r,12 ip65 red/yellow 5.7 (145) o/i & off/on yes yes bdh116 1,3r,12 ip65 black 6.9 (175) o/i & off/on yes yes bdh117 1,3r,12 ip65 red/yellow 6.9 (175) o/i & off/on yes yes cdhxb12 1,3r,4,4x,12 ip65 black 5.7 (145) o/i & off/on yes yes cdhxy12 1,3r,4,4x,12 ip65 red/yellow 5.7 (145) o/i & off/on yes yes cdhxb22 1,3r,4,4x,12 ip65 black 6.9 (175) o/i & off/on yes yes cdhxy22 1,3r,4,4x,12 ip65 red/yellow 6.9 (175) o/i & off/on yes yes bdh8 1,3r,4,4x,12 ip65 metal 8.7 (220) off/on yes terminal lug kit catalog wire terminal numbers for use on: wire size type lugs per kit bdtl25 fd200j_ #6 C 300 kcmil cu/al 6 bdtl175 fd200j (6) #14 C 6 kcmil cu/al 3 bdtl26 fd400j_ #2 C 600 kcmil cu/al 6 bdtl175/400 fd600j C fd800l (12) #14 C 16C600 kcmil cu/al 3 bdtl27 fd600j_ & fd800l_ (2) #2 C 600 kcmil cu/al 6 ? type fuse adapter kit catalog ac thermal ac rated number poles for use on: amp rating voltage bdta2 3 fd200j_ 200 600 bdta4 3 fd400j_ 400 600 bdta6 3 fd600j_ 600 600 bdta8 3 fd800j_ 800 600 protect the promise of customer satisfaction our customer satisfaction team answers your calls 8:00 a.m. C 4:30 p.m. for all us time zones, receiving and responding to an average of 1600 calls and 700 emails every day. we also offer emergency after-hours service. phone: 636-527-3877 email: busscustsat@cooperbussmann.com toll-free fax: 800-544-2570 emergency after-hour phone: 314-995-1342 did you know? bdh112
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 321 disconnects disconnects catalog numbers ul general fuse catalog numbers (1) purpose class nema/ul enclosure type amp rating type 4x plastic 12 7 & 9 30 j efj30p-3pb6 efj302-3pb6 efj307-3pb 30 cc efc30p-3pb6 efc302-3pb6 efc307-3pb 60 j(2) efj60p-3pb8 efj602-3pb6 efj607-3pb 100 j(2) efj100p-3pb8 efj1002-3pb8 efj1007-3pb 200 j(2) efj200p-3pb4 efj2002-3pb4 efj2007-3pb 400 j(2) efj400p-3pb4 efj4002-3pb4 efj4007-3pb 600 j(2) efj600p-3pb4 efj6002-3pb4 efj6007-3pb 800 j(2) efl800p-3pb4 efl8002-3pb4 efl8007-3pb (1) fusible switches are ul listed to the ul98 standard. (2) 600v t type fuse clips may be substituted at no charge. please change the second character of the catalog number from "j" to "t." 30?00a, 600v 3-pole enclosed compact series fusible disconnect switches catalog numbers ul general fuse catalog numbers (1) purpose class/ nema/ul enclosure type amp rating type 1 3r 4 4x stainless 30 j efj301-3pb6 efj303-3pb6 efj304-3pb6 efj30x-3pb6 30 cc efc301-3pb6 efc303-3pb6 efc304-3pb6 efc30x-3pb6 60 j(2) efj601-3pb6 efj603-3pb6 efj604-3pb8 efj60x-3pb8 100 j(2) efj1001-3pb8 efj1003-3pb8 efj1004-3pb8 efj100x-3pb8 200 j(2) efj2001-3pb4 efj2003-3pb4 efj2004-3pb4 efj200x-3pb4 400 j(2) efj4001-3pb4 efj4003-3pb4 efj4004-3pb4 efj400x-3pb4 600 j(2) efj6001-3pb4 efj6003-3pb4 efj6004-3pb4 efj600x-3pb4 800 j(2) efl8001-3pb4 efl8003-3pb4 efl8004-3pb4 efl800x-3pb4 (1) fusible switches are ul listed to the ul98 standard. (2) 600v t type fuse clips may be substituted at no charge. please change the second character of the catalog number from "j" to "t." handle - pistol nema 1, 3r, 4 and 4x, ul fuse class j, cc nema 4x, 12 and 7&9, ul fuse class j, cc efj30x-3pb6 cfd30j3
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 322 disconnects 30?00a, 600v 3-pole enclosed compact series fusible disconnect switches switch ratings ul general maximum horsepower rating purpose single phase three phase wire size for for wire amp rating 120v 200v 240v 200v 208v 240v 480v 600v terminal lugs type approval(1) 30 2 3 5 5 7.5 7.5 15 20 #18 C 8 cu csa, ul 60 3 7.5 10 15 15 15 30 50 #14 C 4 cu csa, ul 100 5 10 15 25 25 30 60 75 #14 C 2/0 cu/al csa, ul 200 50 50 60 125 150 #6 C 300 kcmil cu/al csa, ul 400 100 125 125 250 350 #2 C 600 kcmil cu/al csa, ul 600 150 150 200 400 500 (2) #2 C 600 kcmil cu/al csa, ul 800 200 200 250 500 600 (2) #2 C 600 kcmil cu/al csa, ul (1) fusible switches are ul listed to the ul98 standard. handle ratings catalog catalog amp handle nema numbers no. suffix range type rating color marking defeatable padlockable cdh5s bj 30 selector 1,3r,12 black 0/i & off/on yes yes cdh6s yj 30 selector 1,3r,12 red/yel 0/i & off/on yes yes bdh106 b6 30 pistol 1,3r,12 black 0/i & off/on yes yes bdh107 y6 30 pistol 1,3r,12 red/yel 0/i & off/on yes yes cdhxb65 b6 30 pistol 1,3r,4,4x,12 black 0/i & off/on yes yes cdhxy65 y6 30 pistol 1,3r,4,4x,12 red/yel 0/i & off/on yes yes bdh58 b6 60-100 pistol 1,3r,12 black 0/i & off/on yes yes bdh59 y6 60-100 pistol 1,3r,12 red/yel 0/i & off/on yes yes bdh60 b8 60-100 pistol 1,3r,12 black 0/i & off/on yes yes bdh61 y8 60-100 pistol 1,3r,12 red/yel 0/i & off/on yes yes cdhxb86 b8 60-100 pistol 1,3r,4,4x,12 black 0/i & off/on yes yes cdhxy86 y8 60-100 pistol 1,3r,4,4x,12 red/yel 0/i & off/on yes yes bdh114 b4 200-800 pistol 1,3r,12 black 0/i & off/on yes yes bdh115 y4 200-800 pistol 1,3r,12 red/yel 0/i & off/on yes yes bdh116 b7 200-800 pistol 1,3r,12 black 0/i & off/on yes yes bdh117 y7 200-800 pistol 1,3r,12 red/yel 0/i & off/on yes yes cdhxb12 b4 200-800 pistol 1,3r 4,4x,12 black 0/i & off/on yes yes cdhxy12 y4 200-800 pistol 1,3r 4,4x,12 red/yel 0/i & off/on yes yes cdhxb22 b7 200-800 pistol 1,3r 4,4x,12 black 0/i & off/on yes yes cdhxy22 y7 200-800 pistol 1,3r 4,4x,12 red/yel 0/i & off/on yes yes bdh8 8 200-800 pistol 1,3r 4,4x,12 metal 0/i & off/on no yes easy internet access to product and technical information all of the following functions are available on-line at www .cooperbussmann.com : ? product cross-reference ? product catalogs ? technical specification sheets ? current events/news releases ? training seminar schedule ? training modules ? technical software solutions did you know?
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 323 disconnects disconnects 30?00a 2-, 4- and 6-pole enclosed compact series fusible disconnect switches 2-pole 4-pole 6-pole (2) nema 1, 3r and 4x for transfer, bypass and mechanical interlock applications catalog numbers ul general catalog numbers purpose switch nema enclosure type amp rating type 1 3r 4 4x stainless 30 (class j fuses) 4-pole(1) efj301-4pb6 efj303-4pb6 efj304-4pb6 efj30x-4pb6 6-pole efj301-6pb6 efj303-6pb6 efj304-6pb6 efj30x-6pb transfer efj301-3tb8 efj303-3tb8 efj304-3tb8 efj30x-3tb8 bypass efj301-3bb6 efj303-3bb6 efj304-3bb6 efj30x-3bb6 mech. interlock efj301-3mb6 efj303-3mb6 efj304-3mb6 efj30x-3mb6 30 (class cc fuses) 4-pole(1) efc301-4pb6 efc303-4pb6 efc304-4pb6 efc30x-4pb6 6-pole efc301-6pb6 efc303-6pb6 efc304-6pb6 efc30x-6pb6 transfer efc301-3tb8 efc303-3tb8 efc304-3tb8 efc30x-3tb8 bypass efc301-3bb6 efc303-3bb6 efc304-3bb6 efc30x-3bb6 mech. interlock efc301-3mb6 efc303-3mb6 efc304-3mb6 efc30x-3mb6 60 4-pole(1) efj601-4pb6 efj603-4pb6 efj604-4pb6 efj60x-4pb6 6-pole efj601-6pb4 efj603-6pb4 efj604-6pb4 efj60x-6pb4 transfer efj601-3tb8 efj603-3tb8 efj604-3tb8 efj60x-3tb8 mech. interlock efj601-3mb6 efj603-3mb6 efj604-3mb6 efj60x-3mb6 100 2-pole(1) efj1001-2pb8 efj1003-2pb8 efj1004-2pb8 efj100x-2pb8 4-pole(1) efj1001-4pb8 efj1003-4pb8 efj1004-4pb8 efj100x-4pb8 6-pole efj1001-6pb4 efj1003-6pb4 efj1004-6pb4 efj100x-6pb4 transfer efj1001-3tb8 efj1003-3tb8 efj1004-3tb8 efj100x-3tb8 mech. interlock efj1001-3mb8 efj1003-3mb8 efj1004-3mb8 efj100x-3mb8 200 2-pole(1) efj2001-2pb8 efj2003-2pb8 efj2004-2pb8 efj200x-2pb8 4-pole(1) efj2001-4pb4 efj2003-4pb4 efj2004-4pb4 efj200x-4pb4 6-pole efj2001-6p8 efj2003-6p8 efj2004-6p8 efj200x-6p8 transfer efj2001-3tb4 efj2003-3tb4 efj2004-3tb4 efj200x-3tb4 bypass efj2001-3b6 efj2003-3b6 efj2004-3b6 efj200x-3b6 mech. interlock efj2001-3mb4 efj2003-3mb4 efj2004-3mb4 efj200x-3mb4 400 2-pole(1) efj4001-2pb4 efj4003-2pb4 efj4004-2pb4 efj400x-2pb4 4-pole(1) efj4001-4pb4 efj4003-4pb4 efj4004-4pb4 efj400x-4pb4 6-pole efj4001-6p8 efj4003-6p8 efj4004-6p8 efj400x-6p8 transfer efj4001-3tb4 efj4003-3tb4 efj4004-3tb4 efj400x-3tb4 bypass efj4001-3b6 efj4003-3b6 efj4004-3b6 efj400x-3b6 mech. interlock efj4001-3mb4 efj4003-3mb4 efj4004-3mb4 efj400x-3mb4 600 2-pole(1) efj6001-2pb4 efj6003-2pb4 efj6004-2pb4 efj600x-2pb4 4-pole(1) efj6001-4pb4 efj6003-4pb4 efj6004-4pb4 efj600x-4pb4 6-pole efj6001-6p8 efj6003-6p8 efj6004-6p8 efj600x-6p8 transfer efj6001-3tb4 efj6003-3tb4 efj6004-3tb4 efj600x-3tb4 bypass efj6001-3b6 efj6003-3b6 efj6004-3b6 efj600x-3b6 mech. interlock efj6001-3mb4 efj6003-3mb4 efj6004-3mb4 efj600x-3mb4 800 2-pole(1) efl8001-2pb4 efl8003-2pb4 efl8004-2pb4 efl800x-2pb4 4-pole(1) efl8001-4pb4 efl8003-4pb4 efl8004-4pb4 efl800x-4pb4 6-pole efl8001-6p8 efl8003-6p8 efl8004-6p8 efl800x-6p8 transfer efl8001-3tb4 efl8003-3tb4 efl8004-3tb4 efl800x-3tb4 bypass efl8001-3b6 efl8003-3b6 efl8004-3b6 efl800x-3b6 mech. interlock efl8001-3mb4 efl8003-3mb4 efl8004-3mb4 efl800x-3mb4 (1) iec rated only. (2) = three-poles
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 324 disconnects nema 4x, 12 and 7&9 for transfer, bypass and mechanical interlock applications catalog numbers ul general catalog numbers purpose switch nema enclosure type amp rating type 4x plastic 12 7 & 9 30 (class j fuses) 4-pole(1) efj30p-4pb6 efj302-4pb6 (2) 6-pole efj30p-6pb6 efj302-6pb6 transfer efj30p-3tb8 efj302-3tb8 bypass efj30p-3bb6 efj302-3bb6 mech. interlock efj30p-3mb6 efj302-3mb6 30 (class cc fuses) 4-pole(1) efc30p-4pb6 efc302-4pb6 (2) 6-pole efc30p-6pb6 efc302-6pb6 transfer efc30p-3tb8 efc302-3tb8 bypass efc30p-3bb6 efc302-3bb6 mech. interlock efc30p-3mb6 efc302-3mb6 60 4-pole(1) efj60p-4pb6 efj602-4pb6 (2) 6-pole efj60p-6pb4 efj602-6pb4 transfer efj60p-3tb8 efj602-3tb8 mech. interlock efj60p-3mb6 efj602-3mb6 100 2-pole(1) efj100p-2pb8 efj1002-2pb8 (2) 4-pole(1) efj100p-4pb8 efj1002-4pb8 6-pole efj100p-6pb4 efj1002-6pb4 transfer efj100p-3tb8 efj1002-3tb8 mech. interlock efj100p-3mb8 efj1002-3mb8 200 2-pole(1) efj200p-2pb8 efj2002-2pb8 (2) 4-pole(1) efj200p-4pb4 efj2002-4pb4 6-pole efj200p-6p8 efj2002-6p8 transfer efj200p-3tb4 efj2002-3tb4 bypass efj200p-3b6 efj2002-3b6 mech. interlock efj200p-3mb4 efj2002-3mb4 400 2-pole(1) efj400p-2pb4 efj4002-2pb4 (2) 4-pole(1) efj400p-4pb4 efj4002-4pb4 6-pole efj400p-6p8 efj4002-6p8 transfer efj400p-3tb4 efj4002-3tb4 bypass efj400p-3b6 efj4002-3b6 mech. interlock efj400p-3mb4 efj4002-3mb4 600 2-pole(1) efj600p-2pb4 efj6002-2pb4 (2) 4-pole(1) efj600p-4pb4 efj6002-4pb4 6-pole efj600p-6p8 efj6002-6p8 transfer efj600p-3tb4 efj6002-3tb4 bypass efj600p-3b6 efj6002-3b6 mech. interlock efj600p-3mb4 efj6002-3mb4 800 2-pole(1) efl800p-2pb4 efl8002-2pb4 (2) 4-pole(1) efl800p-4pb4 efl8002-4pb4 6-pole efl800p-6p8 efl8002-6p8 transfer efl800p-3tb4 efl8002-3tb4 bypass efl800p-3b6 efl8002-3b6 mech. interlock efl800p-3mb4 efl8002-3mb4 (1) iec rated only. (2) consult factory for pricing and availability. 30?00a 2-, 4- and 6-pole enclosed compact series fusible disconnect switches (3) = three-poles transfer (3) bypass (3) mechanical interlock (3)
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 325 disconnects disconnects overview for compact series non-fusible disconnect switches cdnf30 cdnf16 catalog number 3-pole cdnf16 cdnf25 cdnf32 cdnf45 cdnf63 cdnf30 cdnf60 cdnf100 cdnf160 general purpose amp rating a 16 25 40 60 80 30 60 100 125 approvals(1) 2-pole n/a n/a n/a n/a n/a n/a n/a n/a ul98 3-pole ul508 ul508 ul508 ul508 ul508 ul98 ul98 ul98 ul98 4-pole ul508 ul508 ul508 ul508 ul508 ul98 ul98 ul98 ul98 technical ratings ul,csa max operating voltage v 600 600 600 600 600 600 600 600 600 max horsepower rating three phase 200 C 208v hp 3 7.5 10 15 20 10 20 25 30 240v hp 5 7.5 10 15 20 10 20 30 30 480v hp 10 15 20 30 40 20 40 50 75 600v hp 10 20 25 30 40 30 40 50 100 single phase 120v hp 1/2 3/4 1 2 2 2 3 5 7.5 240v hp 1.5 2 3 5 5 5 7.5 15 20 short-circuit rating with fuse fuse type cc ka fuse type j ka fuse type t ka fuse type rk1 ka fuse type rk5 ka fuse type l ka fuse type h ka fuse size a technical ratings iec rated insulation and operational voltage ac20 and dc20 v 750 750 750 750 750 750 750 750 750 rated thermal current, ith ac 20/dc 20 open a 25 32 40 63 80 40 63 115 200 ac 20/dc 20 enclosed a 25 32 40 63 80 40 63 115 160 ac 21a 500v a 16 25 32 63 80 40 63 100 160 690v a 16 25 32 63 80 40 63 100 160 rated operational power ac23 400/415v kw 7.5 9 11 22 37 15 18.5 37 75 690v kw 7.5 9 11 15 18.5 15 15 37 75 physical characteristics weight 3-pole lb 0.24 0.24 0.24 0.59 0.59 0.79 0.79 0.79 2.42 dimension 3-pole h in 2.68 2.68 2.68 3.60 3.60 3.94 3.94 3.94 5.00 w in 1.38 1.38 1.38 2.07 2.07 2.76 2.76 2.76 4.96 d in 2.20 2.20 2.20 2.85 2.85 2.95 2.95 2.95 2.93 (1) ul listed switches are also csa certified. cdnf16 to cdnf160 agency information: ul listed, csa certified, iec rated, ce marked cdnf160 10 1010 10 10 10 10 10 10 100 100 50 50 25 50 25 100 10 10 10 10 10 10 100 100 50 50 25 50 25 10 1010 5 5 5 5 5 5 5 105 5 5 30 60 30 60 30 60 100 150 100 150 60 60 100 60 100 200
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 326 disconnects overview for compact series non-fusible disconnect switches catalog number 3-pole bdnf175a bdnf200a bdnf400 bdnf600a bdnf800a bdnf1200 bdnf1600 bdnf2000 bdnf3150 general purpose amp rating a 175 200 400 600 800 1200 1600 2000 3150 approvals(1) 2-pole ul508 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec iec 3-pole ul508 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec ul98 & iec iec 4-pole iec iec ul98 & iec ul98 & iec iec iec iec iec iec technical ratings ul, csa max operating voltage v 600 600 600 600 600 600 600 600 600 max horsepower rating three phase 200 C 208v hp 30 60 100 150 200 240v hp 40 75 125 200 250 480v hp 75 150 250 400 500 600v hp 100 200 350 500 600 single phase 120v hp 240v hp short-circuit rating with fuse fuse type cc ka fuse type j ka 100 fuse type t ka fuse type rk1 ka fuse type rk5 ka 100 100 100 100 fuse type l ka 100 100 100 fuse type h ka fuse size a 200 200 600 600 1200 1200 2000 2000 technical ratings iec rated insulation and operational voltage. ac20 and dc20 v 1000 1000 1000 1000 1000 1000 1000 1000 1000 rated thermal current, ith ac 20/dc 20open a 200 315 630 800 1250 1600 2500 2500 3150 ac 20/dc 20 enclosed a 200 270 630 720 1250 1600 2300 2300 2600 ac 21a 500v a 200 250 630 800 1250 1600 2500 2500 3150 690v a 200 250 630 800 1250 1600 2500 2500 3150 rated operational power ac23 400/415v kw 90 132 315 355 400 400 400 400 400 690v kw 170 200 355 355 physical characteristics weight 3-pole lb 6.61 6.61 13.66 13.66 35.9 38.55 127.7 127.7 127.7 dimension 3-pole h in 8.35 8.35 11.81 11.77 19.09 19.09 25.04 25.04 25.04 w in 7.83 8.62 10.24 11.93 14.29 14.29 18.43 18.43 18.43 d in 4.55 4.55 5.12 5.12 4.92 4.92 10.67 10.67 10.67 (1) ul listed switches are also csa certified. bdnf400a bdnf800a bdnf1600 bdnf175a bdnf175a to bdnf3150 agency information: ul listed, csa certified, iec rated, ce marked
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 327 disconnects disconnects handle - selector 16-100a 3-pole for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle cdnf16 cdnf25 cdnf32 cdh15s ul general maximum horsepower rating catalog purpose iec ac21 single phase three phase terminal lugs numbers amp rating amp rating 120v 240v 240v 480v 600v wire size/type cdnf16 16 16 1 ? 2 1.5 5 10 10 #18-8/cu cdnf25 25 25 3 ? 4 2 7.5 15 20 #18-8/cu cdnf32 40 40 1 3 10 20 25 #18-8/cu cdnf45 60 63 2 5 15 30 30 #14-4/cu cdnf63 80 80 2 5 20 40 40 #14-4/cu cdnf30 30 40 2 5 10 20 30 #14-4/cu cdnf60 60 63 3 7.5 20 40 40 #14-4/cu cdnf100 100 115 5 15 30 50 50 #8-1/0/cu (1) a snap-on fourth pole may be added. all marked both o/i & off/on catalog numbers nema type iec type color defeatable padlockable cdh1s(3) 1 ip54 black cdh2s(3) 1 ip54 red/yellow cdh15s(3) 1 ip54 black yes cdh16s(3) 1 ip54 red/yellow yes cdh3s 1,3r,12 ip65 black yes cdh4s 1,3r,12 ip65 red/yellow yes cdh5s 1,3r,12 ip65 black yes yes cdh6s 1,3r,12 ip65 red/yellow yes yes (3) not suitable for use with cdnf30, 60, 100. mounting depth(2) in inches cdnf16 cdnf30 cdnf25 cdnf45 cdnf60 cdnf32 cdnf63 cdnf100 cdh1s cdh3s cdh1s cdh3s cdh3s shaft cdh2s cdh4s cdh2s cdh4s cdh4s catalog length cdh15s cdh5s cdh15s cdh5s cdh5s numbers in (mm) cdh16s cdh6s cdh16s cdh6s cdh6s cds85s 3.3 (85) 4.2-5.0 3.6-4.3 4.9-5.6 4.4-5.0 3.9-4.9 cds105s 4.1 (105) 5.0-5.8 4.4-5.1 5.7-6.4 5.1-5.8 4.7-5.7 cds120s 4.7 (120) 5.6-6.4 5.0-5.8 6.3-7.0 5.7-6.4 5.3-6.3 cds130s 5.1 (130) 6.0-6.7 5.4-6.1 6.7-7.4 6.1-6.8 5.6-6.7 cds180s 7.1 (180) 7.1-8.7 7.4-8.1 8.6-9.4 8.1-8.7 7.6-8.6 cds250s 9.8 (250) 10.7-11.5 10.1-10.8 11.4-12.1 10.9-11.5 10.4-11.4 cds330s 13 (330) 13.8-14.6 13.3-14.0 14.6-15.3 14.0-14.7 13.5-14.5 (2) mounting depth is the distance from the outside of door to the disconnect switch mounting plate. shaft can be cut to desired length. mounts directly to switch; no shaft necessary catalog numbers nema type color for use on: length (inches) padlockable opmrh 1 red cdnf16, 25, 32 1.0 cdby68306(3) 1 red cdnf30, 45, 60, 63,100 1.4 cdby68419/1(3) 1 red cdnf30, 45, 60, 63,100 1.6 yes(5) cdmc1 metal collar cdnf16 C cdnf100 cdswm5x8 set screw cdnf16, 25, 30, 32, 45, 60, 63, 100 (4) 0.1875" (3/16") diameter shackle required. (5) set screw cdswm5x8 needed with replacement knobs cdby__. 16?00a/600v 3 pole(1) switches shafts ?for use with cdh selector handles  0.20 x 0.20" (  5 x 5 mm) handle - selector ?for use with shafts  0.20 x 0.20" (  5 x 5 mm) knob - replacement 16-100a base & din rail mount compact series non-fusible disconnect switches cds_ s
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 328 disconnects shafts - twisted ?rotates handle 45  0.20 x 0.20" (  5 x 5 mm) mounting depth(1) in inches shaft cdnf16 cdnf30 catalog length cdnf25 cdnf45 cdnf60 numbers in (mm) cdnf32 cdnf63 cdnf100 cds48t 5.9 (150) 6.2-6.7 6.9-7.4 6.4-7.4 cds67t 6.7 (170) 7.0-7.5 7.7-8.1 7.2-8.1 cds49t 10.4 (265) 10.7-11.3 11.4-11.9 10.9-11.9 cds50t 15.8 (400) 16.0-16.6 16.8-17.2 16.2-17.2 (1) mounting depth is the distance from the outside of door to the disconnect switch mounting plate. shaft can be cut to desired length. mounting depth(1) in inches shaft cdnf16 cdnf30 catalog length cdnf25 cdnf45 cdnf60 numbers in (mm) cdnf32 cdnf63 cdnf100 cds48p 5.9 (150) 6.2-6.7 6.9-7.4 6.4-7.4 cds67p 6.7 (170) 7.0-7.5 7.7-8.1 7.2-8.1 cds49p 10.4 (265) 10.7-11.3 11.4-11.9 10.9-11.9 cds50p 15.8 (400) 16.0-16.6 16.8-17.2 16.2-17.2 cds99p 19.7 (500) 20.0-20.5 20.7-21.1 20.1-21.1 (1) mounting depth is the distance from the outside of door to the disconnect switch mounting plate. shaft can be cut to desired length. handle - pistol 16-100a 3-pole for a complete assembly, please select one of each: ? 1 switch ? 1 shaft ? 1 handle cds_p bdh107 cdnf30 cdnf60 cdnf100 ul general maximum horsepower rating catalog purpose iec ac21 single phase three phase terminal lugs numbers amp rating amp rating 120v 240v 240v 480v 600v wire size/type cdnf16 16 16 1 ? 2 1.5 5 10 10 #18-8/cu cdnf25 25 25 3 ? 4 2 7.5 15 20 #18-8/cu cdnf32 40 40 1 3 10 20 25 #18-8/cu cdnf45 60 63 2 5 15 30 30 #14-4/cu cdnf63 80 80 2 5 20 40 40 #14-4/cu cdnf30 30 40 2 5 10 20 30 #14-4/cu cdnf60 60 63 3 7.5 20 40 40 #14-4/cu cdnf100 100 115 5 15 30 50 50 #8-1/0/cu (1) a snap-on fourth pole may be added. catalog length number nema type iec type color marking in (mm) defeatable padlockable bdh104 1,3r,12 ip65 black o/i & off/on 1.8 (45) yes yes bdh105 1,3r,12 ip65 red/yel o/i & off/on 1.8 (45) yes yes bdh106 1,3r,12 ip65 black o/i & off/on 2.6 (65) yes yes bdh107 1,3r,12 ip65 red/yel o/i & off/on 2.6 (65) yes yes cdhxb65 1,3r,12,4,4x ip66 black o/i & off/on 2.6 (65) yes yes cdhxy65 1,3r,12,4,4x ip66 red/yel o/i & off/on 2.6 (65) yes yes 16?00a/600v 3-pole(1) switches shafts ?for use with pistol handles  0.20 x 0.20" (  5 x 5 mm) handle - pistol ?for use with shafts  0.20 x 0.20" (  5 x 5 mm) 16-100a base & din rail mount compact series non-fusible disconnect switches
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 329 disconnects disconnects 16-100a door mounted compact series non-fusible disconnect switches handle - selector 16-100a 3-pole for a complete assembly, please select one of each: ? 1 switch ? 1 handle note: door mounted switches do not provide door interlock. cdnf16d cdnf25d cdnf32d cdh9s cdh13s ul general maximum horsepower rating catalog purpose iec ac21 single phase three phase terminal lugs number amp rating amp rating 120v 240v 240v 480v 600v wire size/type cdnf16d 16 16 1 ? 2 1.5 5 10 10 #18-8/cu cdnf25d 25 25 3 ? 4 2 7.5 15 20 #18-8/cu cdnf32d 40 40 1 3 10 20 25 #18-8/cu cdnf45d 60(4) 63 2 5 15 30 30 #14-4/cu cdnf63d 80(4) 80 2 5 20 40 40 #14-4/cu cdnf30d 30(4) 40 2 5 10 20 30 #14-4/cu cdnf60d 60(4) 63 3 7.5 20 40 40 #14-4/cu cdnf100d 100(4) 115 5 15 30 50 50 #8-1/0/cu (1) a snap-on fourth pole may be added. (2) door mounted switches do not require shafts. (3) cdnf16, 25, 32, 45 & 63 door mounted switches will not accept pistol handles. (4) cdnf45 & 63 door mounted switches can only use screw mounted handles. handles - selector all marked both o/i & off/on catalog nema numbers type iec type color defeatable padlockable snap-on mounting ?for use on cdnf16, 25, 32d cdh7s 1 ip54 black cdh8s 1 ip54 red/yellow cdh19s 1 ip54 black yes cdh20s 1 ip54 red/yellow yes cdh9s 1,3r,12 ip65 black yes cdh10s 1,3r,12 ip65 red/yellow yes screw mounting ?for use on cdnf16, 32, 45 & 63d cdh11s 1 ip54 black cdh12s 1 ip54 red/yellow cdh17s 1 ip54 black yes cdh18s 1 ip54 red/yellow yes cdh13s 1,3r,12 ip65 black yes cdh14s 1,3r,12 ip65 red/yellow yes handle adapter - pistol grip catalog number description for use on: cdhzx6 adapter piece for pistol grip handle cdnf30d, cdnf60d, cdnf100d 16?00a/600v 3 pole (1)(2)(3) switches note: the model pistol grip handles used on the non-door mounted switches shown on the bottom of page 321, are the available handles.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 330 disconnects 400-800a non-fusible compact series disconnect switches shafts - twisted ?rotates handle 45  0.47 x 0.47" (  12 x 12 mm) catalog shaft length mounting depth(1) numbers in (mm) in inches bds28045 11.0 (280) 10.2-14.5 bds32545 12.8 (325) 12.0-16.3 bds46545 18.3 (465) 17.5-21.9 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. shafts ?for use with pistol handles  0.47 x 0.47" (  12 x 12 mm) catalog shaft length mounting depth(1) numbers in (mm) in inches bds280 11.0 (280) 10.2-14.5 bds325 12.8 (325) 12.0-16.3 bds395 15.6 (395) 14.8-19.1 bds465 18.3 (465) 17.5-21.9 bds535 21.1 (535) 20.3-24.6 (1) mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. handle - pistol 400-800a 2-, 3- and 4-pole for a complete assembly, please select one of each: ? 1 switch ? 1 handle ? 1 shaft ? 1 terminal lug kit switches 400-800a/600v ul general catalog purpose iec ac21 maximum horsepower rating number poles amp rating amp rating 200v 208v 240v 480v 600v bdnf4002 2 400 630 bdnf600a2 2 600 800 bdnf800a2 2 800 1250 bdnf400 3 400 630 100 100 125 250 350 bdnf600a 3 600 800 150 150 200 400 500 bdnf800a 3 800 1250 200 200 250 500 600 bdnf4004 4 400 630 100 100 125 250 350 bdnf600a4 4 600 800 150 150 200 400 500 bdnf800a4 4 1250 200 200 250 500 600 handles - pistol ?for use with shafts  0.47 x 0.47 (  12 x 12 mm) catalog length number nema type iec type color in (mm) marking defeatable padlockable bdh112 1,3r,12 ip65 blk 4.9 (125) o/i & off/on yes yes bdh113 1,3r,12 ip65 r/y 4.9 (125) o/i & off/on yes yes bdh114 1,3r,12 ip65 blk 5.7 (145) o/i & off/on yes yes bdh115 1,3r,12 ip65 r/y 5.7 (145) o/i & off/on yes yes bdh116 1,3r,12 ip65 blk 6.9 (175) o/i & off/on yes yes bdh117 1,3r,12 ip65 r/y 6.9 (175) o/i & off/on yes yes cdhxb12 1,3r,4,4x,12 ip66 blk 5.7 (145) o/i & off/on yes yes cdhxy12 1,3r,4,4x,12 ip66 r/y 5.7 (145) o/i & off/on yes yes cdhxb22 1,3r,4,4x,12 ip66 blk 6.9 (175) o/i & off/on yes yes bdh8 1,3r,4,4x,12 ip65 metal 8.7 (220) off/on yes lug kits - terminal catalog lugs numbers for use on: wire size/type per kit bdtl26 bdnf400 #2-600 kcmil/cu/al 6 bdtl262 bdnf400 (2) #2-500 kcmil/cu/al 6 bdtl27 bdnf600a (2) #2-600 kcmil/cu/al 6 bdtl30 bdnf800a (2) #2-600 kcmil/cu/al 6 bdtl32 bdnf800a1 (8) 2/0 + (2)#2 600 kcmil/cu/al 3 bdtl175/400 bdnf400-bdnf600a(1) (12) #14-6/cu/al 3 (1) a load side distribution lug eliminates the need to purchase, install and wire a separate distribution block. bds280 bdnf600a bdtl175/400
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 331 disconnects disconnects accessories for 400-800a compact series non-fusible disconnect switches auxiliary contacts ( 2 ) catalog ac thermal ac rated numbers description for use on: amp rating voltage bdaux1 1 no + 1 nc bdnf400 C 10 600 bdaux2 2 no + 2 nc bdnf800a 10 600 bdaux3 4 no + 4 nc bdnf800a 10 600 bdaux4 2 no bdnf800a 10 600 bdaux5 4 no bdnf800a 10 600 bdaux6 8 no bdnf800a 10 600 (2) ul file e57057 terminal poles catalog ac thermal ac rated number description for use on: amp rating voltage bdzx85 detachable neutral bdnf400 C 400 600 mounts on side of bdnf600a 400 600 switch or din rail terminal shrouds catalog numbers description for use on: bdts4 includes one bdnf400 bdts6a shroud for line or bdnf600a bdts8a load side bdnf800a handle support bracket catalog numbers description for use on: bdzx73 allows handle to be directly bdnf400 C mounted to switch bdnf600a bdzx71 behind the door bdnf800a bdaux1-6 bdzx85 bdts bdzx71
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 332 disconnects 16?0a, 600v 3-pole enclosed compact series non-fusible disconnect switches enf321-3pbj selector handle nema 1, 3r, 4 & 4x catalog numbers ul general catalog numbers purpose nema enclosure type (1) amp rating 1 3r 4 4x stainless 16 enf161-3pbj enf163-3pbj enf164-3pbj enf16x-3pbj 25 enf251-3pbj enf253-3pbj enf254-3pbj enf25x-3pbj 40 enf321-3pbj enf323-3pbj enf324-3pbj enf32x-3pbj 60 enf451-3pbj enf453-3pbj enf454-3pbj enf45x-3pbj 80 enf631-3pbj enf633-3pbj enf634-3pbj enf63x-3pbj (1) enclosures are rated as listed, selector handles are only nema rated 1, 3r, 12. the overall nema rating of an enclosed switch with a selector handle is 1, 3r, 12. selector handle nema 4x and 12, iec ip65 catalog numbers ul general catalog numbers purpose nema enclosure type iec enclosure type amp rating 4x plastic(1) 12(1) ip65 plastic 16 enf16p-3pbj enf162-3pbj enf16e-3pbj 25 enf25p-3pbj enf252-3pbj enf25e-3pbj 40 enf32p-3pbj enf322-3pbj enf32e-3pbj 60 enf45p-3pbj enf452-3pbj enf45e-3pbj 80 enf63p-3pbj enf632-3pbj enf63e-3pbj (1) enclosures are rated as listed, selector handles are only nema rated 1, 3r, 12. the overall nema rating of an enclosed switch with a selector handle is 1, 3r, 12. enf252-3pyj enf16e-3pbj enf45e-3pbj selector handle ratings, 600v amp nema cat. no. catalog rating rating color marking detachable padlockable suffix number 16-100 1, 3r, 12 black o/i & off/on yes yes bj cdh5s 16-100 1, 3r, 12 red/yel o/i & off/on yes yes yj cdh6s note: all enclosed switches come with a black handle. however, most handles can be substituted with a red/yellow handle. please substitute the handle suffix code (1st and 2nd from last characters) with the red/yellow handle catalog number suffix li sted in the table to the left. there is no additional cost for a red/yellow handle of equal rating and style. example: a red/yellow selector handle for an enf161-3pbj can be substituted for the black selector handle by using the "yj" suffix instead of the "bj" suffix, new catalog #enf161-3pyj.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 333 disconnects disconnects 16a-3150a, 600v 3-pole enclosed compact series non-fusible disconnect switches note: all enclosed switches come with a black handle. however, most handles can be substituted with a red/yel- low handle. please substi- tute the handle suffix code (1st and 2nd from last char- acters) with the red/yellow handle catalog number suffix listed in the table to the left. there is no additional cost for a red/yellow handle of equal rating and style. example: a red/yellow pis- tol handle for an enf161- 3pbj can be substituted for the black selector handle by using the "yj" suffix instead of the "bj" suffix, new cata- log #enf161-3pyj. pistol handle nema 4x, 12 and 7 & 9, iec ip65 catalog numbers ul general catalog numbers purpose agency nema enclosure type iec enclosure type amp rating listing 4x plastic 12 7 & 9 ip65 plastic 16 ul 508 enf16p-3pb6 enf162-3pb6 enf167-3p enf16e-3pb4 25 ul 508 enf25p-3pb6 enf252-3pb6 enf257-3p enf25e-3pb4 40 ul 508 enf32p-3pb6 enf322-3pb6 enf327-3p enf32e-3pb4 60 ul 508 enf45p-3pb6 enf452-3pb6 enf457-3p enf45e-3pb4 80 ul 508 enf63p-3pb6 enf632-3pb6 enf637-3p enf63e-3pb4 30 ul 98 enf30p-3pb6 enf302-3pb6 enf307-3p enf30e-3pb6 60 ul 98 enf60p-3pb6 enf602-3pb6 enf607-3p enf60e-3pb6 100 ul 98 enf100p-3pb6 enf1002-3pb6 enf1007-3p enf100e-3pb6 125 ul 98 enf125p-3pb6 enf1252-3pb6 enf125e-3pb6 200 ul 98 enf200p-3pb8 enf2002-3pb8 400 ul 98 enf400p-3pb4 enf4002-3pb4 600 ul 98 enf600p-3pb4 enf6002-3pb4 800 ul 98 enf800p-3pb4 enf8002-3pb4 1200 ul 98 enf1200p-3pb4 enf12002-3pb4 1600 ul 98 enf1600p-3p8 enf16002-3p8 2000 ul 98 enf2000p-3p8 enf20002-3p8 3150(2) ul 98 enf3150p-3p8 enf31502-3p8 (2) iec rated only. enf25p-3py6 enf63x-3pb6 pistol handle nema 1, 3r, 4 & 4x catalog numbers ul general catalog numbers purpose agency nema enclosure type amp rating listing 1 3r 4 4x stainless 16 ul 508 enf161-3pb6 enf163-3pb6 enf164-3pb6 enf16x-3pb6 25 ul 508 enf251-3pb6 enf253-3pb6 enf254-3pb6 enf25x-3pb6 40 ul 508 enf321-3pb6 enf323-3pb6 enf324-3pb6 enf32x-3pb6 60 ul 508 enf451-3pb6 enf453-3pb6 enf454-3pb6 enf45x-3pb6 80 ul 508 enf631-3pb6 enf633-3pb6 enf634-3pb6 enf63x-3pb6 30 ul98 enf301-3pb6 enf303-3pb6 enf304-3pb6 enf30x-3pb6 60 ul98 enf601-3pb6 enf603-3pb6 enf604-3pb6 enf60x-3pb6 100 ul98 enf1001-3pb6 enf1003-3pb6 enf1004-3pb6 enf100x-3pb6 125 ul98 enf1251-3pb6 enf1253-3pb6 enf1254-3pb6 enf125x-3pb6 200 ul98 enf2001-3pb8 enf2003-3pb8 enf2004-3pb8 enf200x-3pb8 400 ul98 enf4001-3pb4 enf4003-3pb4 enf4004-3pb4 enf400x-3pb4 600 ul98 enf6001-3pb4 enf6003-3pb4 enf6004-3pb4 enf600x-3pb4 800 ul98 enf8001-3pb4 enf8003-3pb4 enf8004-3pb4 enf800x-3pb4 1200 ul98 enf12001-3pb4 enf12003-3pb4 enf12004-3pb4 enf1200x-3pb4 1600 ul98 enf16001-3p8 enf16003-3p8 enf16004-3p8 enf1600x-3p8 2000 ul98 enf20001-3p8 enf20003-3p8 enf20004-3p8 enf2000x-3p8 3150(2) ul98 enf31501-3p8 enf31503-3p8 enf31504-3p8 enf3150x-3p8 (2) iec rated only. pistol handle ratings: 16-3150a, 600v amp nema cat. no. catalog rating rating color marking detachable padlockable suffix number 16-100 1, 3r, 12 black o/i & off/on yes yes b6 bdh106 1, 3r, 12 red/yel o/i & off/on yes yes y6 bdh107 1, 3r, 4, 4x, 12 black o/i & off/on yes yes b6 cdhxb65 1, 3r, 4, 4x, 12 red/yel o/i & off/on yes yes y6 cdhxy65 125 1, 3r, 12 black o/i & off/on yes yes b6 bdh120 1, 3r, 12 red/yel o/i & off/on yes yes y6 bdh121 1, 3r, 4, 4x, 12 black o/i & off/on yes yes b8 cdhxb86 1, 3r, 4, 4x, 12 red/yel o/i & off/on yes yes y8 cdhxy86 200 1, 3r, 12 black o/i & off/on yes yes b8 bdh110 1, 3r, 12 red/yel o/i & off/on yes yes y8 bdh111 1, 3r, 4, 4x, 12 black o/i & off/on yes yes b8 cdhxb88 1, 3r, 4, 4x, 12 red/yel o/i & off/on yes yes y8 cdhxy88 400-3150 1, 3r, 12 black o/i & off/on yes yes b4 bdh114 1, 3r, 12 red/yel o/i & off/on yes yes y4 bdh115 1, 3r, 12 black o/i & off/on yes yes b7 bdh116 1, 3r, 12 red/yel o/i & off/on yes yes y7 bdh117 1, 3r, 4, 4x, 12 black o/i & off/on yes yes b4 cdhxb12 1, 3r, 4, 4x, 12 red/yel o/i & off/on yes yes y4 cdhxy12 1, 3r, 4, 4x, 12 black o/i & off/on yes yes b7 cdhxb22 1, 3r, 4, 4x, 12 red/yel o/i & off/on yes yes y7 cdhxy22 1, 3r, 4, 4x, 12 metal o/i & off/on no yes 8 bdh8
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 334 disconnects 16-400a 2-, 4- and 6-pole enclosed compact series non-fusible disconnect switches nema 4x, 12 and 7&9 for transfer, bypass and mechanical interlock applications catalog numbers ul general catalog numbers purpose switch nema enclosure type amp rating type 1 3r 4 4x stainless 16 4-pole enf161-4pb6 enf163-4pb6 enf164-4pb6 enf16x-4pb6 6-pole enf161-6pb6 enf163-6pb6 enf164-6pb6 enf16x-6pb6 transfer enf161-3tb8 enf163-3tb8 enf164-3tb8 enf16x-3tb8 bypass enf161-3bb8 enf163-3bb8 enf164-3bb8 enf16x-3bb8 mech. interlock enf161-3mb6 enf163-3mb6 enf164-3mb6 enf16x-3mb6 25 4-pole enf251-4pb6 enf253-4pb6 enf254-4pb6 enf25x-4pb6 6-pole enf251-6pb6 enf253-6pb6 enf254-6pb6 enf25x-6pb6 transfer enf251-3tb8 enf253-3tb8 enf254-3tb8 enf25x-3tb8 bypass enf251-3bb8 enf253-3bb8 enf254-3bb8 enf25x-3bb8 mech. interlock enf251-3mb6 enf253-3mb6 enf254-3mb6 enf25x-3mb6 40 4-pole enf321-4pb6 enf323-4pb6 enf324-4pb6 enf32x-4pb6 6-pole enf321-6pb6 enf323-6pb6 enf324-6pb6 enf32x-6pb6 transfer enf321-3tb8 enf323-3tb8 enf324-3tb8 enf32x-3tb8 bypass enf321-3bb8 enf323-3bb8 enf324-3bb8 enf32x-3bb8 mech. interlock enf321-3mb6 enf323-3mb6 enf324-3mb6 enf32x-3mb6 60 4-pole enf451-4pb6 enf453-4pb6 enf454-4pb6 enf45x-4pb6 6-pole enf451-6pb6 enf453-6pb6 enf454-6pb6 enf45x-6pb6 transfer enf451-3tb8 enf453-3tb8 enf454-3tb8 enf45x-3tb8 bypass enf451-3bb8 enf453-3bb8 enf454-3bb8 enf45x-3bb8 mech. interlock enf451-3mb6 enf453-3mb6 enf454-3mb6 enf45x-3mb6 80 4-pole enf631-4pb6 enf633-4pb6 enf634-4pb6 enf63x-4pb6 6-pole enf631-6pb6 enf633-6pb6 enf634-6pb6 enf63x-6pb6 transfer enf631-3tb8 enf633-3tb8 enf634-3tb8 enf63x-3tb8 bypass enf631-3bb8 enf633-3bb8 enf634-3bb8 enf63x-3bb8 mech. interlock enf631-3mb6 enf633-3mb6 enf634-3mb6 enf63x-3mb6 30 4-pole enf301-4pb6 enf303-4pb6 enf304-4pb6 enf30x-4pb6 6-pole enf301-6pb6 enf303-6pb6 enf304-6pb6 enf30x-6pb6 transfer enf301-3tb8 enf303-3tb8 enf304-3tb8 enf30x-3tb8 bypass enf301-3bb8 enf303-3bb8 enf304-3bb8 enf30x-3bb8 mech. interlock enf301-3mb6 enf303-3mb6 enf304-3mb6 enf30x-3mb6 60 4-pole enf601-4pb6 enf603-4pb6 enf604-4pb6 enf60x-4pb6 6-pole enf601-6pb6 enf603-6pb6 enf604-6pb6 enf60x-6pb6 transfer enf601-3tb8 enf603-3tb8 enf604-3tb8 enf60x-3tb8 bypass enf601-3bb8 enf603-3bb8 enf604-3bb8 enf60x-3bb8 mech. interlock enf601-3mb6 enf603-3mb6 enf604-3mb6 enf60x-3mb6 100 4-pole enf1001-4pb6 enf1003-4pb6 enf1004-4pb6 enf100x-4pb6 6-pole enf1001-6pb6 enf1003-6pb6 enf1004-6pb6 enf100x-6pb6 transfer enf1001-3tb8 enf1003-3tb8 enf1004-3tb8 enf100x-3tb8 bypass enf1001-3bb8 enf1003-3bb8 enf1004-3bb8 enf100x-3bb8 mech. interlock enf1001-3mb6 enf1003-3mb6 enf1004-3mb6 enf100x-3mb6 125 2-pole enf1251-2pb6 enf1253-2pb6 enf1254-2pb6 enf125x-2pb6 4-pole enf1251-4pb6 enf1253-4pb6 enf1254-4pb6 enf125x-4pb6 6-pole enf1251-6pb2 enf1253-6pb2 enf1254-6pb4 enf125x-6pb4 transfer enf1251-3tb8 enf1253-3tb8 enf1254-3tb8 enf125x-3tb8 bypass mech. interlock enf1251-3mb6 enf1253-3mb6 enf1254-3mb8 enf125x-3mb8 200 2-pole enf2001-2pb8 enf2003-2pb8 enf2004-2pb8 enf200x-2pb8 4-pole enf2001-4pb8 enf2003-4pb8 enf2004-4pb8 enf200x-4pb8 6-pole enf2001-6pb4 enf2003-6pb4 enf2004-6pb4 enf200x-6pb4 transfer enf2001-3tb4 enf2003-3tb4 enf2004-3tb4 enf200x-3tb4 bypass enf2001-3bb4 enf2003-3bb4 enf2004-3bb4 enf200x-3bb4 mech. interlock enf2001-3mb8 enf2003-3mb8 enf2004-3mb8 enf200x-3mb8 400 2-pole enf4001-2pb4 enf4003-2pb4 enf4004-2pb4 enf400x-2pb4 4-pole enf4001-4pb4 enf4003-4pb4 enf4004-4pb4 enf400x-4pb4 6-pole enf4001-6p8 enf4003-6p8 enf4004-6p8 enf400x-6p8 transfer enf4001-3tb4 enf4003-3tb4 enf4004-3tb4 enf400x-3tb4 bypass enf4001-3b6 enf4003-3b6 enf4004-3b6 enf400x-3b6 mech. interlock enf4001-3mb4 enf4003-3mb4 enf4004-3mb4 enf400x-3mb4 (3) = three-poles transfer (3) bypass (3) mechanical interlock (3)
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 335 disconnects disconnects 16-400a 2-, 4- and 6-pole enclosed compact series non-fusible disconnect switches nema 4x, 12 and 7&9, and iec ip65 for transfer, bypass and mechanical interlock applications catalog numbers ul general catalog numbers purpose switch nema enclosure type iec enclosure type amp rating type 4x plastic 12 7 & 9 ip65 16 4-pole enf16p-4pb6 enf162-4pb6 enf167-4p enf16e-4pbj 6-pole enf16p-6pb6 enf162-6pb6 enf167-6p enf16e-6pbj transfer enf16p-3tb8 enf162-3tb8 enf167-3t bypass enf16p-3bb8 enf162-3bb8 enf167-3b mech. interlock enf16p-3mb6 enf162-3mb6 25 4-pole enf25p-4pb6 enf252-4pb6 enf257-4p enf25e-4pbj 6-pole enf25p-6pb6 enf252-6pb6 enf257-6p enf25e-6pbj transfer enf25p-3tb8 enf252-3tb8 enf257-3t bypass enf25p-3bb8 enf252-3bb8 enf257-3b mech. interlock enf25p-3mb6 enf252-3mb6 40 4-pole enf32p-4pb6 enf322-4pb6 enf327-4p enf32e-4pbj 6-pole enf32p-6pb6 enf322-6pb6 enf327-6p enf32e-6pbj transfer enf32p-3tb8 enf322-3tb8 enf327-3t bypass enf32p-3bb8 enf323-3bb8 enf327-3b mech. interlock enf32p-3mb6 enf322-3mb6 60 4-pole enf45p-4pb6 enf452-4pb6 enf457-4p enf45e-4pbj 6-pole enf45p-6pb6 enf452-6pb6 enf457-6p enf45e-6pbj transfer enf45p-3tb8 enf452-3tb8 enf457-3t bypass enf45p-3bb8 enf452-3bb8 enf457-3b mech. interlock enf45p-3mb6 enf452-3mb6 80 4-pole enf63p-4pb6 enf632-4pb6 enf637-4p enf63e-4pbj 6-pole enf63p-6pb6 enf632-6pb6 enf637-6p enf637-6pbj transfer enf63p-3tb8 enf632-3tb8 enf637-3t bypass enf63p-3bb8 enf632-3bb8 enf637-3b mech. interlock enf63p-3mb6 enf632-3mb6 30 4-pole enf30p-4pb6 enf302-4pb6 enf307-4p enf30e-4pb4 6-pole enf30p-6pb6 enf302-6pb6 enf307-6p enf30e-6pb6 transfer enf30p-3tb8 enf302-3tb8 enf307-3t bypass enf30p-3bb8 enf302-3bb8 enf307-3b mech. interlock enf30p-3mb6 enf302-3mb6 60 4-pole enf60p-4pb6 enf602-4pb6 enf607-4p enf60e-4pb4 6-pole enf60p-6pb6 enf602-6pb6 enf607-6p enf60e-6pb6 transfer enf60p-3tb8 enf602-3tb8 enf607-3t bypass enf60p-3bb8 enf602-3bb8 enf607-3b mech. interlock enf60p-3mb6 enf602-3mb6 100 4-pole enf100p-4pb6 enf1002-4pb6 enf1007-4p enf100e-4pb4 6-pole enf100p-6pb6 enf1002-6pb6 enf1007-6p enf100e-6pb6 transfer enf100p-3tb8 enf1002-3tb8 enf1007-3t bypass enf100p-3bb8 enf1002-3bb8 enf1007-3b mech. interlock enf100p-3mb6 enf1002-3mb6 125 2-pole enf125p-2pb6 enf1252-2pb6 enf1257-2p 4-pole enf125p-4pb6 enf1252-4pb6 enf1257-4p 6-pole enf125p-6pb2 enf1252-6pb2 enf1257-6p transfer enf125p-3tb8 enf1252-3tb8 enf1257-3t bypass mech. interlock enf125p-3mb6 enf1252-3mb6 200 2-pole enf200p-2pb8 enf2002-2pb8 enf2007-2p 4-pole enf200p-4pb8 enf2002-4pb8 enf2007-4p 6-pole enf200p-6pb4 enf2002-6pb4 enf2007-6p transfer enf200p-3tb4 enf2002-3tb4 enf2007-3t bypass enf200p-3bb4 enf2002-3bb4 enf2007-3b mech. interlock enf200p-3mb8 enf2002-3mb8 400 2-pole enf400p-2pb4 enf4002-2pb4 enf4007-2p 4-pole enf400p-4pb4 enf4002-4pb4 enf4007-4p 6-pole enf400p-6p8 enf4002-6p8 enf4007-6p transfer enf400p-3tb4 enf4002-3tb4 enf4007-3t bypass enf400p-3b6 enf4002-3b6 enf4007-3b mech. interlock enf400p-3mb4 enf4002-3mb4
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 336 disconnects a/c disconnects fused and non-fused data sheet: 1143 series b22__ specifications description: fused and non-fused rainproof air conditioner pullout units. dimensions: see catalog numbers table. construction: nema 3r rainproof metal housing with weather resistant coating. wire range: 14-3 awg, al/cu ratings: phase: single, 2-wire volts: 240vac amps: 30-60a agency information: ul listed to ul 1429, c-ul certified, ul guide wgew features and benefits ? a/c disconnects meet nec ? code requirements under articles 440.14. gfci units meet nec ? code requirements under articles 210.63, 210.8, and 406.8(b)(1). ? nema 3r rainproof enclosures withstand outdoor environment. ? padlockable with two-position pullout handle to lock safety shield when in the on position. (not available on gf or na units.) for added safety, pullout handle can be stored in the compartment in the off position. ? easy installation: knockouts on back, bottom and both sides, cable whip versions save labor. typical applications ? residential, light industrial/commercial a/c and heat pump service. ? spas/whirlpools, swimming pools, pump houses ? suitable for service entrance equipment applications with field installable ground bar, kit number dpfg. metallic fused disconnect metallic non-fused disconnect catalog numbers fused disconnect max hp rating wire range enclosure fuse approx. dimensions (in) catalog numbers description rating 120v 240v 60 or 75c cu/al type class height width depth b221-30f 30a, pullout 30a 1.5 3 #14-3 nema 3r h or r 8 3 ? 4 5 3 ? 8 2 7 ? 8 b221-30fgf 30a, pullout w/ gfci 30a 1.5 3 #14-3 nema 3r h or r 13 7 1 ? 2 4 3 ? 4 b222-60f 60a, pullout 60a 3 10 #14-3 nema 3r h or r 8 3 ? 4 5 3 ? 8 2 7 ? 8 b222-60fgf 60a, pullout w/ gfci 60a 3 10 #14-3 nema 3r h or r 13 7 1 ? 2 4 3 ? 4 non-fused b222-60nf 60a, pullout 60a 3 10 #14-3 nema 3r * 8 3 ? 4 5 3 ? 8 2 7 ? 8 b222-60nfgf 60a, pullout w/ gfci 60a 3 10 #14-3 nema 3r * 11 3 ? 4 6 1 ? 2 4 1 ? 2 b222-60nfna 60a, switch 60a * 10 #14-3 nema 3r * 8 3 ? 4 5 3 ? 8 3 5 ? 8 non-fused cable whip b222-60nf12w 60a, pullout w/ 1 ? 2 " cable whip 60a* 3 10 #14-3 nema 3r * 14 3 ? 4 12 1 ? 2 4 b222-60nf34w 60a, pullout w/ 3 ? 4 " cable whip 60a** 3 10 #14-3 nema 3r * 14 3 ? 4 12 1 ? 2 4 cable whip specifications max upstreamwire pullout overcurrent harness ground hot flexible conduit catalog numbers description rating protection device diameter wire size wire size length (ft) non-metallic fittings b222-60nf12w 60a, pullout w/ 1 ? 2 " cable whip 60a 30a 1 ? 2 " #10 #10 6 1 - 90, 1 - straight b222-60nf34w 60a, pullout w/ 3 ? 4 " cable whip 60a 50a 3 ? 4 " #8 #10 6 1 - 90, 1 - straight * upstream overcurrent protection device (ocpd) not to exceed 30 amps. **upstream overcurrent protection device (ocpd) not to exceed 50 amps. b222-60nf34w non-fused with cable whip metallic non-fused disconnect with gfci receptacle.
for product data sheets, visit www .cooperbussmann.com/products/datasheet.asp 337 disconnects disconnects fused, dead front disconnect switches 15149 series specifications description: fused, dead front disconnect switches ratings: volts: 600vac amps: 0-30a sccr: 200,000a rms sym. dielectric sccr: 2200v motor rating: 5hp poles: 2 to 3 agency information: ul recognized, file e116716 for general industrial installations. guide wfxv2. csa certified, file lr37129-6. examined under the new proposed standard ul 1429 which imparts a stricter set of test conditions than the former program that combined the applicable portions for ul 512 (fuse holders) and ul 98 (enclosed switches). features and benefits ? fuse holders in the pull-out head eliminate possibility of electric shock while changing fuse. ? accepts class j fuses ordering information to order, specify: 15149 + number of poles. example: 15149-2 = 2-pole device. data sheet: 1141 all-inclusive elevator disconnect simplifies installation plus a multitude of codes and standards when the westin hotel chain renovated the historic cupples station in downtown st. louis, the hotels design-and-build electrical contractor specified the cooper bussmann ? power module? elevator shunt trip disconnect. the primary reason was the savings in man-hours with everything in one box: the fire alarm, control wiring and power wiring; all the parts needed to interface with a fire alarm system in a ul 98 listed assembly. in addition, all the codes and standards surrounding the elevator disconnecting means C electrical, elevator, fire alarm and the sprinkler system C are met, including ansi/asme a17.1, nfpa 72, nec ? 620.62. the contractor faced a unique situation when the luxury hotel chain chose to revamp the old warehouse versus tearing the structure down and rebuilding. the hotel complex consists of four buildings interconnected with walkways. a total of eight elevators were installed with eight power module switches, two per building. each 30 hp passenger elevator is fused with cooper bussmann ? low-peak ? class j lpj-70sp fuses while each 40hp service elevator uses the class j lpj-90sp fuses. did you know?
338 cooper bussmann ? services provide productivity through protection with a focus on critical issues related to enhancing the bottom line: ? downtime reduction; ? workplace safety; and ? code compliance. you can easily avoid costly shutdowns and delays that noncompliance issues cause when you have the right information. the cooper bussmann innovative oscar? (online short- circuit current ul508a rating) compliance software is the companys most recent offering to help you comply with the new code and standards requirements for short-circuit current ratings. underwriters laboratories (ul) now requires all electrical panels and assemblies manfactured to standard 508a to be marked with their sccr. article 409 of the 2005 national electrical code also mandates that industrial control panels be marked with an assembly sccr. getting the assembly sccr correct can be daunting. but the companys oscar compliance software easily guides users through the steps of entering the panels components for supply, feeder, sub-feeder and branch circuits. based upon the component types or part numbers entered, the software determines the assembly sccr per ul508a supplement sb. it includes the following features. ? its automatic. the software determines the assembly sccr of industrial control panel assemblies per ul508a sb based upon component types or part numbers. ? its simple. just use the assembly parts list C the oscar compliance software is backed by a database containing more than 50,000 line item part numbers with their component sccr. ? available online. its available 24/7, 365 days a year with a one-year subscription. ? printed documentation is available. the oscar compliance software generates a spreadsheet for assembly documentation of components and assembly sccr. ? its continually updated. the oscar compliance software is regularly updated with new part numbers, their component sccrs, and any changes that may occur to code requirements and agency standards. ? its customizable. the custom device option allows users to enter specialized information not usually encountered in most assembly components. once you have calculated your short- circuit current rating and you find its too low for the application, cooper bussmann services now offers sccr design-engineering assistance to raise your rating to required levels. in an ever-changing regulatory environment, cooper bussmann services can help you stay in compliance and focused on what you do best. for more information and to purchase an annual, open-ended use of the cooper bussmann oscar compliance software, visit www .cooperb ussmann.com/sccr or contact your cooper bussmann representative. eliminate the guesswork in assembly sccr calculations